Induction power directly determines line capacity and unit energy consumption. Selection depends on three indicators: steel blank diameter, hourly output and target temperature rise range.
For steel blanks over 100 mm in diameter, thick cross-section requires deep penetration heating, so medium-frequency power supply of 1000 kW or above shall be configured.
Simple power calculation reference: Power consumption for heating steel blank from ambient temperature to rolling forming temperature is about 400–450 kWh per ton. Total required power can be reversely calculated combined with target hourly output, balancing production efficiency and long-term electricity cost.